Laboratory

Equipment

RELAB Laboratory Instrumentation and Equipment

The RELAB Laboratory is equipped with two calibrated calorimeters for testing equipment with a capacity of up to 100 kW, as well as dedicated test benches for domestic hot water systems, gas-fired heat pumps, and static air-to-air heat exchangers.

+ 500

people

departmental Community

18

groups

research

41

laboratories

over 8,300 mq

€ 27 mln

value of projects

funded in 2025

The calorimeter consists of two climatic chambers (an indoor chamber and an outdoor chamber) that allow the operating conditions, in terms of temperature and humidity, of the indoor and outdoor environments (residential, commercial, or technical) in which the units under test are typically installed to be reproduced within the tolerance ranges prescribed by the relevant standards. In the indoor chamber, air temperatures can range from 5°C to 60°C, while in the outdoor chamber they can range from -30°C to 60°C. The chambers are equipped with hydronic circuits supporting flow rates from 0.1 m³/h to 5 m³/h. The two calorimeter chambers can be used separately for monobloc units or simultaneously for split systems (indoor and outdoor units) and units requiring ducted test configurations. In addition to air conditioning parameters, the calorimeter can also control the temperature and flow rates of fluids (water and brine) supplied to the units under test. The laboratory instrumentation enables the measurement of thermal capacity and performance indicators (COP, SCOP, EER, SEER, GUE, and SGUE) required by technical standards, as well as electrical parameters (power, current, voltage, phase shift, etc.), flow rate, temperature, and pressure losses in the hydronic circuits of the units under test, motor speed, air velocity and pressure (or pressure difference) for ducted units, and natural gas consumption and pressure for thermally driven units.

The calorimeter consists of two climatic chambers (Chamber 1 and Chamber 2), each capable of testing units with a maximum rated capacity of 50 kW. By opening the central partition wall, the two chambers can be combined into a single climatic chamber for testing monobloc units with capacities of up to 100 kW. Both climatic chambers can reproduce the temperature conditions prescribed by technical standards, ranging from -30°C to +60°C, as well as the required humidity conditions. The chambers are equipped with hydronic circuits supporting flow rates of up to 25 m³/h.

The two chambers can be used separately for monobloc units or simultaneously for systems with separate indoor and outdoor units, as well as for units requiring ducted test configurations. In addition to controlling air conditions, the calorimeter can also regulate the temperature and flow rates of fluids (water and brine) supplied to the units under test.The laboratory instrumentation enables the measurement of thermal capacity and performance indicators (COP, SCOP, EER, SEER, GUE, and SGUE) required by technical standards, as well as electrical parameters (power, current, voltage, phase shift, etc.), flow rate, temperature, and pressure losses in the hydronic circuits of the units under test, motor speed, air velocity and pressure (or pressure difference) for ducted units, and natural gas consumption and pressure for thermally driven units.The climatic chambers of the 100 kW calorimeter are also used to perform accredited acoustic tests using the hard-wall method. In particular, microphones connected to a multichannel analyzer and a reference sound source are used to determine the sound power level of a source under test, such as a heat pump or fan coil unit. In addition, dedicated setups inside the chambers allow intensity-based acoustic testing and the mapping of the directivity and sound power of the source under test using microphone arrays.

Sia nel Calorimetro da 25 kW che in quello da 100 kW sono presenti due banchi prova per pompe di calore per la produzione di acqua calda sanitaria (ACS) dotati di strumentazione e circuitazione idronica progettata e interamente dedicata alla conduzione di prove secondo norma EN16147.
Both the 25 kW and 100 kW calorimeters are equipped with two dedicated test benches for domestic hot water heat pumps. The benches feature instrumentation and hydronic circuits specifically designed to perform tests in accordance with the EN 16147 standard. The test benches are fully automated and allow the testing of domestic hot water systems with either integrated or separate storage tanks. They can perform the draw-off cycles prescribed by the standard or customized cycles defined according to the manufacturer’s specifications, while recording all the main parameters of interest, including water flow rate, water inlet and outlet temperatures, tank temperatures, water pressure, pressure losses, and electrical power consumption.

Two test benches for gas-powered equipment have been installed in the 25 kW and 100 kW calorimeter chambers. These can be used to test equipment such as absorption heat pumps, hybrid systems, boilers, and internal combustion engine-driven heat pumps. The chambers are equipped with all the instrumentation and safety systems required to perform tests according to the main applicable standards, such as EN 12309 and VDI 4650 Part 2, as well as for the development of equipment and components using either natural gas from the grid or gas supplied by a certified gas cylinder system. The system is managed through a dedicated software tool and enables the monitoring and recording of all the main parameters of interest, including air temperature and humidity, water flow rate, gas flow rate and pressure, water and gas inlet and outlet temperatures, hydronic pressure losses, and electrical power consumption.

The laboratory is equipped with integrating sound level meters, microphones, intensity probes, acoustic calibrators, reference sound sources, a configurable multichannel analyzer for different types of measurements, and a multichannel system with a microphone array for acoustic mapping using beamforming and acoustic holography.

This instrumentation enables the laboratory to perform:

Acoustic mapping of sound sources to identify noisy components or areas with the highest sound emissions.

General sound pressure measurements.

Sound power measurements of machines installed in situ using intensity-based methods, and of machines installed in the calorimeter test chambers using pressure-based methods.

Characterization of sound sources in terms of spectrum and directivity.

Audio recordings.

Other Laboratory Pages

Laboratory

Testing and Services

Accredited Testing Services and Technical Consulting

Laboratory

Tested Equipment

RELAB’s facilities enable the assessment of the thermal and acoustic performance of a wide range of equipment.

Interested in our services?

Contact us for more information about our testing services and research collaborations.
+39 02 2399 3868 – info-relab@polimi.it

Scroll to Top